{"id":739,"date":"2024-10-08T15:23:02","date_gmt":"2024-10-08T19:23:02","guid":{"rendered":"https:\/\/www.aquacure-jeffro-dev.linksdev.com\/?post_type=product-resource&#038;p=739"},"modified":"2024-10-09T16:30:19","modified_gmt":"2024-10-09T20:30:19","slug":"can-the-aquacure-make-a-room-explode","status":"publish","type":"product-resource","link":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/product-resource\/can-the-aquacure-make-a-room-explode\/","title":{"rendered":"\u00bfPuede el AquaCure hacer explotar una habitaci\u00f3n?"},"content":{"rendered":"<p>Hydrogen gas (the part of BG that is combustible) needs to be at least 4% in air by volume before it is combustible.<br \/>\nHydrogen rises VERY fast and diffuses in air VERY fast, so even a minimal ventilation would prevent a combustible mixture from forming in the room.<br \/>\nLet\u2019s do some math. \u00a0A 3 meter cube (a small room) contains 27,000 liters of space. \u00a04% of 27,000 is 1,080 liters.<br \/>\nAssuming your electrolyzer makes 50 liters of hydrogen per hour, there would be (at least) 20 hours of continous use before a combustible mixture could form.<br \/>\nBUT: Hydrogen is a very tiny molecule and can fit through the smallest of cracks (it even travels through metals). \u00a0So it is almost impossible to contain in a room that has ANY ventilation. \u00a0Just opening a door once in awhile will ventilate a room enough to prevent a combustible mixture.<br \/>\nAnd this doesn\u2019t take into account if a person is breathing the BG, so some of the hydrogen is being \u2018consumed\u2019 by the breather(s); just like oxygen is a room is consumed by breather(s).<br \/>\nSo, for practicality, just assume that if the room is ventilated well enough so that the breather(s) have enough fresh oxygen to breathe, that there can NEVER be a combustible mixture in the room (from an electrolyzer producing such small quantities of hydrogen).<\/p>","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"product-resource-group":[97,98,100,101],"restricted-resource-tag":[],"class_list":["post-739","product-resource","type-product-resource","status-publish","hentry","product-resource-group-ac50-resources","product-resource-group-ea-h160-resources","product-resource-group-browns-gas-book-1-resources","product-resource-group-browns-gas-book-2-resources"],"acf":[],"_links":{"self":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/product-resource\/739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/product-resource"}],"about":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/types\/product-resource"}],"wp:attachment":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/media?parent=739"}],"wp:term":[{"taxonomy":"product-resource-group","embeddable":true,"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/product-resource-group?post=739"},{"taxonomy":"restricted-resource-tag","embeddable":true,"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/restricted-resource-tag?post=739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}