{"id":783,"date":"2024-10-08T16:39:40","date_gmt":"2024-10-08T20:39:40","guid":{"rendered":"https:\/\/www.aquacure-jeffro-dev.linksdev.com\/?post_type=product-resource&#038;p=783"},"modified":"2024-10-15T16:59:05","modified_gmt":"2024-10-15T20:59:05","slug":"how-do-i-measure-browns-gas-production","status":"publish","type":"product-resource","link":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/product-resource\/how-do-i-measure-browns-gas-production\/","title":{"rendered":"\u00bfC\u00f3mo mido la producci\u00f3n de gas de Brown?"},"content":{"rendered":"<p>Do I need to make an elaborate volume test apparatus like you show in ER_VolumeTestApparatus.doc in order to measure gas production?<br \/>\nNo, that&#8217;s overkill for what you need. \u00a0The VTA allows you to take reasonably accurate measurements without assistance.<br \/>\nYou can get reasonably accurate gas volume by timing the filling of a pop bottle underwater, IF you do it correctly.<br \/>\nNOTE: Beware of tests:1.\u00a0Like this one, because the weight of the bottle isn&#8217;t accounted for (the bottle weight is pressurizing the gas), so there is actually MORE gas production than &#8216;indicated&#8217;.2. Like this one, that pushes the hose deep underwater, (because the electrolyzer builds pressure when the hose is that deep. \u00a0The &#8216;extra&#8217; pressure\/gas is then released when the bottle is at &#8216;ambient&#8217; pressure), so there is LESS gas than &#8216;indicated&#8217;.<br \/>\nYou&#8217;ll need an assistant, a stopwatch, a couple of containers, a pen and paper.<br \/>\n1. Find an appropriate sized bottle. \u00a0For an ER50 I&#8217;d use one that is about 0.5 liter in volume.<br \/>\n2. Carefully measure the EXACT volume of the bottle, (in mL or cc). \u00a0Use a measuring cup, graduated beaker or syringe to find the exact volume of the bottle by measuring the water it takes to fill it (it&#8217;ll be more than the stated volume on the side of the bottle).<br \/>\n3. Find a bucket large enough to easily fill the bottle with water and turn the bottle upside down.<br \/>\n4. Fill the bucket with warm (room temperature) water; so your hands don&#8217;t get cold while holding them submerged and the gas can be at Standard Ambient Temperature and Pressure (SATP).<br \/>\n5. Start your electrolyzer and let it warm up (it will be more efficient at higher temperature).<br \/>\n6. Have an assistant stand by to operate a stopwatch (an iPhone app works fine) and take notes on paper (I prefer to make a chart like a spreadsheet).<br \/>\n7. Submerge the bottle in the bucket and allow it to fill with water.<br \/>\n8. Turn the bottle upside down so that the opening is down and raise it out of the water so that the opening is only about 1 inch submerged (the water will stay in the bottle).<br \/>\n9. Make sure the electrolyzer won&#8217;t shut off during the duration of the test, (reset the timer if needed).<br \/>\n10. Submerge the gas hose under the water about 1 inch and wait for the bubbles to stabilize (about 5 seconds should do it for an ER50). \u00a0The deeper you go, the more pressure the ER50 would need to build (which is &#8216;gas storage&#8217;) which would skew your &#8216;volume&#8217; results. \u00a0You need to have the electrolyzer gas pressure as near ambient as possible for most accurate results.<br \/>\n11. Raise the bottle about 1\/2&#8243; (do NOT lift it out of the water) and insert the gas hose under it (so bubbles now enter the bottle)&#8230; At the SAME TIME have your assistant start the stopwatch.Water will now come out of the bottle as gas goes in.<br \/>\n12. Keep timing until the gas completely fills the bottle, then stop the stopwatch.<br \/>\nWrite down the results. \u00a0It&#8217;s best if your assistant does this as your hands will be wet.<br \/>\nNow you have a volume and a time. \u00a0So lets do the math.<br \/>\nYou are looking for volume\/time. \u00a0Scientific Standard is Liters per Hour (L\/hr)<br \/>\n1 hour is 3600 seconds. \u00a0Volume is in liter (1000 ml or 1000 cc)<br \/>\nFor comparison, if the electrolyzer filled a 1 liter bottle in one minute (60 seconds) you&#8217;d have a gas production of 60 L\/hr. \u00a0Less time is more L\/hr. \u00a0More time is less L\/hr.<br \/>\nSo an ER50 (rated to produce at least 50 liters of BG in an hour) should fill a 0.5 liter bottle in just over 36 seconds.<br \/>\nThe actual math looks like this:<br \/>\n3600 (seconds in an hour) \/ 50 liters = 72 seconds to fill a 1 liter bottle. \u00a072 (seconds) \u00a0* 0.5 (volume of bottle) = 36 seconds<br \/>\nSo in an actual experiment, if it took 50 seconds to fill a 0.5 liter bottle you&#8217;d find the liters \/ hour with this formula:<br \/>\n(3600 \/ seconds recorded) * 0.5 (volume of bottle in liters) =<br \/>\n(3600 \/ 50) * 0.5 = 36 liters per hour.<\/p>","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"product-resource-group":[99,100,101,126],"restricted-resource-tag":[],"class_list":["post-783","product-resource","type-product-resource","status-publish","hentry","product-resource-group-er50-resources","product-resource-group-browns-gas-book-1-resources","product-resource-group-browns-gas-book-2-resources","product-resource-group-browns-gas-pump-resources"],"acf":[],"_links":{"self":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/product-resource\/783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/product-resource"}],"about":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/types\/product-resource"}],"wp:attachment":[{"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/media?parent=783"}],"wp:term":[{"taxonomy":"product-resource-group","embeddable":true,"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/product-resource-group?post=783"},{"taxonomy":"restricted-resource-tag","embeddable":true,"href":"https:\/\/aquacure-jeffro-dev.linksdev.com\/es\/wp-json\/wp\/v2\/restricted-resource-tag?post=783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}